- Now once the gas supply is checked, you can take the old valve out. Use your toolkit to loosen the screws. ...
- Fit the new valve. Use your toolkit to fix everything in place as not doing so will be a hazard to your safety. ...
- Check the new valve by turning the gas back on. The pressure must be adequate. If not, you can rest it to get it to work.
- Always call a specialist before things start getting out of hand. ...
Full Answer
How do you replace a furnace gas valve?
– Turn off the furnace at the wall control. … – Take out the bolts in the service panel on the side of the furnace using a nut driver. … – Pull the wires off the gas valve terminals. … – Turn the test control on the multimeter to “mV,” which stands for millivolt.
How to replace the gas control valve on your furnace?
Instructions for Replacing the Gas Valve on a Furnace
- Turn Off Circuit Breaker. Turn off the furnace's circuit breaker.
- Turn the Gas Shutoff Valve. Close the furnace's gas cock knob—the gas pipe's shutoff valve. ...
- Disconnect the Electrical Components. ...
- Position the Adjustable Wrench. ...
- Rotate the Intake Pipe. ...
- Remove the Old Gas Valve. ...
- Check the New Gas Valve. ...
- Apply Pipe Thread Compound. ...
- Connect the New Gas Valve. ...
Is the gas valve on my furnace bad?
Troubleshooting a Furnace Gas Valve. If 24 volts is coming from the board to the gas valve terminals and you don’t hear that little clicking noise the internal valve makes, you could have a bad gas valve. To double-check, take the leads off to the gas valve and check there. Got 24 volts? Then something downstream of that 24 volts is not working.
How much does a furnace gas valve replacement cost?
Keep a carbon monoxide detector in your furnace area. A furnace gas valve costs anywhere from $200 to $600 to replace. This part allows natural gas or propane to flow to your unit. It’s usually attached to the thermocouple for emergency cutoff when necessary.

Can a gas valve on a furnace be repaired?
In some instances you can repair a gas valve on a furnace depending on what is causing it to not work properly. However, repairing your gas valve is not usually the most cost effective option since it can be just as expensive to have your gas valve repaired as it would be to have your entire gas valve replaced.
How do I know if my furnace gas valve is bad?
Here are some signs that indicate your furnace has a bad gas valve.A Gas Leak. This is a major indicator that something could be wrong with the gas valve in your furnace. ... A Total Shutdown of the Furnace. ... A Flooded Furnace. ... Get Expert Services.
How do you fix a furnace gas valve that is stuck?
7:4711:33Fixing Stuck Gas Valve - Works Every Time | Installing propane FurnaceYouTubeStart of suggested clipEnd of suggested clipThis one isn't popping up it's supposed to push it up and it's not popping it up. So what i've doneMoreThis one isn't popping up it's supposed to push it up and it's not popping it up. So what i've done is just taken both of those plungers. Out of the gas valve assembly.
What causes furnace gas valve failure?
The valve itself may have simply worn out or may be damaged due to basement seepage or submersion. Alternately, one of the electronic gas ignition components or a glitch in the safety circuit may be to blame. If your furnace has a standing pilot light, the thermocouple could be worn out.
How much should it cost to replace a gas valve on a furnace?
$300 to $750 dollarsAverage Cost To Replace the Gas Valve on Your Furnace? According to sites like Home Advisor and CostEstimates.com, replacing the gas valve on your furnace can cost anywhere from $300 to $750 dollars. This includes the part itself and the services of an HVAC professional.
How much does it cost to replace a gas valve on a furnace?
A furnace gas valve replacement costs $200 to $800 on average. Furnace gas valve prices are $75 to $300 for the part alone or up to $600 for original manufacturer parts (OEM). Gas valve replacement labor costs $125 to $500.
Can you clean a gas valve?
Turn off electrical power and shut the furnace gas valve. Use a medium-bristled brush to sweep content off each burner and sweep out the combustion chamber as best you can. Use a straw or compressed air to blow dust and dirt off the pilot light assembly or hot surface ignitor, as well as the flame sensor.
What opens gas valve on furnace?
The thermocouple (or thermopile) generates the power holds the safety valve open. Additionally, the thermocouple remains immersed in the pilot light flame. Without adequate heating of the thermocouple or thermopile, the furnace gas valve closes. As a result, this cuts off the supply of gas to the pilot light.
How long do gas valves last?
Gas Valves are routinely checked for 100,000 cycles and are used in equipment that have approximately 15 years life expectancy.
How do you diagnose a bad gas valve?
1:125:43How to test a Gas Valve - YouTubeYouTubeStart of suggested clipEnd of suggested clipYou can set this here. And you want you should have 24 volts. Within 3 seconds 3 to 5 seconds of theMoreYou can set this here. And you want you should have 24 volts. Within 3 seconds 3 to 5 seconds of the hot surface igniter beginning to glow. If the hot surface igniter never begins to glow.
How do you test a gas control valve?
How to Check the Furnace Gas Valve With a MultimeterTurn off the furnace at the wall control. ... Take out the bolts in the service panel on the side of the furnace using a nut driver. ... Pull the wires off the gas valve terminals. ... Turn the test control on the multimeter to "mV," which stands for millivolt.More items...
How long do furnace gas valves last?
Gas Valves are routinely checked for 100,000 cycles and are used in equipment that have approximately 15 years life expectancy.
How do you test a gas solenoid valve?
1:142:30Dryer Won't Heat? Gas Valve Coil Testing, Troubleshooting - YouTubeYouTubeStart of suggested clipEnd of suggested clipThe coil should indicate a resistance between 300 and 2000 ohms. Now keeping the probe on the commonMoreThe coil should indicate a resistance between 300 and 2000 ohms. Now keeping the probe on the common terminal move the other probe to the third terminal.
How do I know if my Honeywell gas control valve is bad?
0:392:21Troubleshoot Faulty Honeywell Gas Valve 9007885 - YouTubeYouTubeStart of suggested clipEnd of suggested clipTo see yet to see the actual gas pilot light itself and it's lit. After holding it for 90 secondsMoreTo see yet to see the actual gas pilot light itself and it's lit. After holding it for 90 seconds you will hear it click on if you don't you either have a bad thermal pile or a faulty gas valve.
What are the problems with natural gas furnaces?
Most natural gas furnaces have few operational difficulties. Problems typically. involve the pilot light, the thermocouple, or some part of the electrical system. On some gas furnaces and heaters, a plug-type door covers the pilot light assembly. To gain access to the pilot burner, pull the door out of the furnace housing.
How to access pilot burner on a furnace?
To gain access to the pilot burner, pull the door out of the furnace housing. On other units, remove the panel that covers the pilot and gas burners. The pilot light controls, reset buttons, gas valves, and thermocouple are usually contained in an assembly at the front of the furnace.
How high should the pilot flame be on a gas stove?
To adjust the height of the pilot flame, turn the flame adjustment screw until the flame is from 11/2 to 2 inches high.
How far apart should you set the pointer for gas leaks?
The pointers should be set about 25 degrees apart. Set the upper pointer at about 115 degrees Fahrenheit and the lower one at about 90 degrees Fahrenheit. If you smell gas while performing these repairs, you'll want to get that leak taken care of right away. Learn how to find gas leaks on the next page.
How to replace a thermocouple?
Step 1: Unscrew copper lead and connection nut inside threaded connection to gas line. Under mounting bracket at thermocouple tube, unscrew bracket nut that holds tube in place. Step 2: Insert new thermocouple into hole in bracket.
Why won't my furnace stay lit?
If it won't stay lit after several attempts, you may have faulty thermocouple. If pilot flame still won't stay lit, call professional service person. Some furnaces have an electrical system to ignite the gas; in these systems there is no pilot light. Instead, an electric element heats up and ignites the burners.
Why does my pilot light go out on my furnace?
The pilot light on a gas furnace can go out because of drafts. To relight the pilot, follow the manufacturer's instructions exactly; they are usually fastened to the furnace. If instructions for relighting the pilot are not provided, follow this general procedure: Step 1: Find pilot light assembly.
Furnace gas valve troubleshooting
To troubleshoot a furnace gas valve, the first thing you need to check is the furnace’s sequence of operations.
Replacing a furnace gas valve
Replacing a furnace gas valve is a tough job. In fact, in many areas, it may be illegal for you to do it yourself since it comes into contact with your municipal gas system.
Why does my furnace igniter crack?
However, over time, the constant heat/cool cycles cause the igniter to crack and fail.
Why does my furnace overheat?
A clogged air filter restricts airflow through the heat exchanger, causing the furnace to overheat. The high-limit switch detects the dangerous overheating and signals the computer to shut off the burners and run the blower fan to cool off the heat exchanger. Once the furnace cools, the computer tries to fire up again.
Where is the flame sensor located on a furnace?
The igniter and flame sensor are located inside a sealed combustion chamber and aren’t usually visible. But they can be replaced without removing the combustion chamber cover.
What is a high efficiency furnace?
High-efficiency furnaces are jam-packed with valves, sensors, motors and flue pipes. We’ve removed many of those larger components from this furnace so you can see what the parts look like and where they’re located. They won’t be as easy to see in your furnace.
How efficient are condensing furnaces?
Some of the components are complex in themselves and require special equipment to diagnose and repair. But other parts are pretty straightforward and easy to replace.
Can you replace an inducer fan motor?
But the fan requires special sealants and procedures to ensure it doesn’t leak any carbon monoxide into your home. Screw this up and you could kill somebody. Leave this one to the pros.
Can furnace dealers give out parts numbers?
Some furnace dealers won’t give out parts numbers or sell parts to DIYers. And appliance parts stores don’t always stock parts for every brand. In that case, search the Internet for “furnace parts” and enter your furnace brand and model number to find the right parts ( theignitorstore.com is one source).

Working of The Valve
- You should know that there are only specific types of boilers and furnaces that work with the gas valves. So when there is a unit that works with a gas valve, you will be able to find two units of valves that together make up the gas valve. The pilot light uses the primary light for gas supply and the burner trays receive gas from the secondary valve which is also called the main valve. T…
Know Your Gas Valve Type
- The two types of gas valves that you can find in the different units of furnaces are gas chain valves and combination valves. 1. The gas chain valve consists of the solenoid valve, the manual valve, and pilot safety. This type of valve will let you close and open the gas valve manually. 2. The combination gas valve though does not require all the different valves in the gas chain valve an…
Troubleshooting Tips For Gas Valves
- The pilot light should always be on. If it is not, you will need to light it up. For this, you can follow the manual that might have been provided to you. Or you can always call us to know more.
- You will have to wait for a little while for the second valve to open as it needs adequate power from the pilot light.
- The pilot light should always be on. If it is not, you will need to light it up. For this, you can follow the manual that might have been provided to you. Or you can always call us to know more.
- You will have to wait for a little while for the second valve to open as it needs adequate power from the pilot light.
- The thermopile should be producing an adequate voltage for the primary valve to stay open. There is a definite need for a replacement if the voltage is not enough.
- In case you would like to know an estimate of the cost of replacement, let us know. We will be happy to help you.
Maintenance
- A house with a furnace is very comfortable in the winter season. But the furnace needs to be taken care of to avoid the immature wearing out of its parts. A typical furnace can be used for up to 20 years. However, after a certain point, some issues cannot be neglected. It not only affects the working of the furnace but also the power consumption at your place. While the furnace mig…
The Necessary Types of Equipment Required
- If you need to figure out if the gas valve requires replacement then you can contact us for more information. If you have figured out that your valve requires replacement then you can proceed further. You can always contact us for any assistance needed anywhere in the process. Here are the things that you will be needing for the replacement: 1. A basic toolkit 2. The accurate valve t…