how to repair wilkins backflow preventer

by Mrs. Susana Stanton Published 1 year ago Updated 1 year ago
image

Place a wrench on the top stem and hold the relief valve piston with the other hand and unscrew the piston to free the diaphragm. The relief valve disc is located on the bottom of the stem. The relief valve disc is free once you unscrew the stem from the disc retainer. Reassemble the relief valve in reverse order.

Part of a video titled Repairing a Zurn Wilkins 975XL Reduced Pressure Principle ...
2:40
4:31
You want to disassemble the cartridge by unscrewing the seal ring screw. Inspect the diaphragmMoreYou want to disassemble the cartridge by unscrewing the seal ring screw. Inspect the diaphragm closely for wear or holes inspect the o-ring on the upper plunger for cuts or damage.

Full Answer

What is a backflow preventer and how does it work?

What is a Backflow Preventer?

  • Types of Backflow Preventers. These devices are provided with two check valves to keep contaminants out of the clean water. ...
  • Signs of a Broken Backflow Preventer. A broken backflow preventer in your pipes may result in discolored or cloudy water, which can cause health issues such as nausea and diarrhea.
  • Inspection of your backflow prevention device. ...

How to test a reduced pressure principle backflow?

What are 2 ways to prevent backflow?

  • An air gap. Air gaps are different than other backflow prevention devices because they’re non-mechanical.
  • A Reduced Pressure Principle Backflow Preventer (RPBP).
  • A barometric loop.
  • A pressure type vacuum breaker.
  • A hose bib backflow preventer.

What is the critical level of a backflow preventer?

• Provide protection against backsiphonage only. • Can be used where it is under continuous pressure from the water supply (valving permitted downstream). • This assembly has a critical level of installation of 6 inches (152 mm) above the flood level rim. • The assembly must be accessible for field testing and maintenance.

When is a backflow preventer required?

When is a Backflow Preventer Required? Backflow prevention assemblies are designed to prevent contaminated water from mixing into clean municipal water supplies, which are usually used as drinking water.

image

How do I know if my backflow preventer is bad?

Water Flow Is Slow One of the simplest signs that your backflow preventer is bad stems from the flow of water. You may not know until it's too late—like if the fire sprinklers go off for the first time in a while.

How do you fix a broken backflow?

5:217:46Broken Backflow Preventer, How to Repair - YouTubeYouTubeStart of suggested clipEnd of suggested clipIt's important to screw this on. But only to screw it on hand tight. Screwing it down hand tight weMoreIt's important to screw this on. But only to screw it on hand tight. Screwing it down hand tight we can now put the belt. Back on and tighten this down. Before.

What causes a backflow preventer to fail?

Backflow prevention assemblies are designed to provide decades of protection. There are many regional conditions that can shorten the working life of a backflow preventer. Conditions such as excessive pressure, water quality, temperature or turbidity can all cause the assembly to deteriorate in its performance.

How do you unclog a backflow preventer?

To remove a malfunctioning preventer, shut off the water-supply valve and purge the heating system so that its water level is below the preventer. If it's connected to the supply pipe with a threaded fitting, use a pair of wrenches to back off the union nuts on both ends of the preventer.

What are the parts of a backflow preventer?

Backflow Repair PartsReduced Pressure Zone Assembly (RPZ) Parts.Pressure Vacuum Breaker (PVB) Parts.Ball Valve Replacements.Backflow Test Cocks.Double Check Assembly (DCA) Parts.Y-Strainers.

How long does a backflow preventer last?

The backflow devices are considered “non-testable” and the only required maintenance is rebuild or replacement of the device once every five years.

Can you replace a valve on a backflow preventer?

0:0011:13FAST and EASY Backflow preventer repair. Ball Valve replacement.YouTubeStart of suggested clipEnd of suggested clipYou can buy this as a single unit. But it's about seventy dollars or so where I was able to find theMoreYou can buy this as a single unit. But it's about seventy dollars or so where I was able to find the exact ball valve I needed on Amazon for about fourteen. So big cost savings there.

Why is my backflow device leaking?

2:044:01How to fix a leaking backflow preventer - YouTubeYouTubeStart of suggested clipEnd of suggested clipSo take the cover. And the spring. And the yo ring out and you're going to look inside remove. ThisMoreSo take the cover. And the spring. And the yo ring out and you're going to look inside remove. This parts called a poppet. And you might see debris here. And we do there's a bit of gravel. Or rusty

What causes backflow in pipes?

Back pressure occurs when the pressure in the system is greater than in its supply, i.e. the system pressure has been increased by some means. Back siphonage results from the supply pressure being lowered below that of the system; often taking place when the supply is interrupted or drained down.

Why is my backflow making noise?

A backflow preventer will often chatter at very low flow rates, since it's designed to close if flow stops. Unless you can increase the flow on those drip zones, the noise will persist. Replacing it with the same spec valve will not stop the chatter.

Why is my backflow device leaking?

Why is my backflow preventer leaking? Backflow preventers can leak because of dirt in the valve or problems with the high pressure and low pressure inside the valve body.

What is a Wilkins 720A?

The Wilkins 720A is a pressure vacuum breaker that is offered in ½”- 2” sizes. The original version began production in 1975 as the model 720. In 1984, Wilkins redesigned the air inlet valve and the model number became 720A. The “A” air inlet valve will work for both the 720 and 720A. Prior to 2010, the test cocks were located on the body ...

How does a check valve spring work?

Getting the spring out can be a little tricky. We found the easiest way is by compressing the spring down on one side – this should cause the spring to pop up over the brass lip.

How to loosen a Bonnet?

To help loosen the bonnet, place a screwdriver on the three brass pegs and turn counter clockwise. Once the bonnet is off, you can remove the plastic washer and bonnet o-ring. The poppet assembly is free once the bonnet is. removed.