For successful condenser fan motor replacement, follow this brief step by step guide:
- Purchase the parts you need.
- Turn the power off.
- Remove the motor and the grill.
- Note which way the fan blades sit to ensure the new fan is placed in the right direction.
- Put the fan on the new motor.
- Connect the wiring, ensuring the wires are kept away from the blade and following the schematic on the new motor. ...
- Screw the motor back on to the grill.
How do you replace a condenser fan?
How do you replace a condenser fan motor on a refrigerator?
- Repair Difficulty. [00:09]
- Before you begin. [00:26]
- Shut off the power. [00:30]
- Remove the condenser fan motor. [00:36]
- Install the new condenser fan motor. [00:52]
- Reinstall the rear compartment cover. [01:04]
- Restore electrical power. [01:09]
How to replace a condensing fan motor?
- Gather the correct replacement parts and required tools. Ensure power to the unit is turned off.
- Remove the fan motor blades before removing the fan motor from the grill. ...
- Complete the wiring, taking care the connection is correct.
- Replace all covers and test the system to ensure that it is working correctly.
Should I replace condenser?
You should replace the entire unit when…
- Your AC is 8+ years (or older) The efficiency of an AC unit is at its best for the first 10 to 12 years of its life. ...
- Obsolete Evaporator Coil All ACs have a SEER (Seasonal Energy Efficiency Ratio) rating. ...
- Your AC unit uses R-22
Do I have to replace condenser?
Thus, it might be a good idea to replace a condenser when your compressor fails. What’s more, when a compressor fails, there is a tremendous amount of debris that is suddenly injected into the AC system. This debris comes from the failed compressor, and it’s almost impossible to remove this debris completely from the condenser.

Can you fix a condenser fan motor?
As we're in the heart of air conditioner season, you may find yourself dealing with an expired condenser fan motor. Fortunately, this is a repair that can be done by non-professionals. Start by confirming the issue is in fact a motor in need of replacement. Begin by turning off the power to the A.C. unit.
What causes a condenser fan motor to fail?
The main causes of failure are loss of lubricant, a failed run capacitor, a failed bearing in a belt drive, a little water dripping into the windings or a voltage problem.
Can you fix a condenser fan?
0:576:25Central Air Condenser Fan Motor Replacement - YouTubeYouTubeStart of suggested clipEnd of suggested clipAnd the motor will need to be replaced. Condenser fan motors are usually unique to each central airMoreAnd the motor will need to be replaced. Condenser fan motors are usually unique to each central air condensing unit.
How do you take apart a condenser fan motor?
0:105:24Condenser Fan Motor Autopsy - YouTubeYouTubeStart of suggested clipEnd of suggested clipIn one a turn and sometimes it'll squeal really loud so what I'm gonna do today just for fun is justMoreIn one a turn and sometimes it'll squeal really loud so what I'm gonna do today just for fun is just to pull this motor apart as you can see I've already got the bolts out of it.
How do I know if my condenser fan motor is bad?
5 Signs Your AC Fan Motor Is BadThe cooling fans won't turn on.The fan turns on when the AC is running, but the blades rotate slowly.You can hear a rattling noise coming from the condenser unit.It smells like something's burning.Blown fuse.
How do you test a condenser fan motor?
0:124:50Outdoor HVAC Unit Fan Motor! Step by Step Troubleshooting, Capacitor ...YouTubeStart of suggested clipEnd of suggested clipAll right this particular one is a 35 + v UF capacitor. Alright so the higher number is actually forMoreAll right this particular one is a 35 + v UF capacitor. Alright so the higher number is actually for the compressor. And the lower number will be for the fan motor. You can verify.
What happens if condenser fan doesn't work?
at BURNED-OUT COMPRESSOR, if the condensing unit fan is not working the compressor itself may shut down or even be ruined by overpressure or over temperature.
Will AC work without condenser fan?
The fan won't start even though the AC is on When the AC runs without the fan circulating air, it can eventually lead to the evaporator coils freezing over. Once this happens, your air conditioning unit is at risk of suffering more serious damage. Turn the AC off and call an HVAC technician.
How do you troubleshoot a fan motor?
3:445:18How I Troubleshoot an Air Conditioner Condenser Fan Motor - YouTubeYouTubeStart of suggested clipEnd of suggested clipCheck between the frame of the motor. And each winding. Common start and run make sure that you'reMoreCheck between the frame of the motor. And each winding. Common start and run make sure that you're not using a painted surface for the frame. Either you want to use a metallic base for this. Test.
How much does a condenser fan motor cost?
between $300 and $500The average cost of a condenser fan motor is between $300 and $500 (not including installation). If the compressor breaks, you are looking at a much costlier problem which could cost up to $2000. In some cases, your fan motor may be under warranty.
What causes AC fan motor to burn up?
Like any motor, an air conditioner fan motor can become overheated if it works too hard and doesn't receive proper maintenance. If your AC has worked for you most of the summer, the stress could cause the fan motors to burn out.
How long do condenser fan motors last?
More likely is a lifespan of 10 to 20 years which means by the time the AC motor fails it's often time to consider replacing the entire system. One reason they last so long is they are designed and manufactured to withstand extreme heat up to 140℉.
What causes a fan motor to burn out?
Inadequate air flow within the system. Buildup of dust, dirt, or debris. Electrical problems, including an excessive voltage supply. Motor insulation failing prematurely due to high temperatures.
How long should a condenser fan motor last?
More likely is a lifespan of 10 to 20 years which means by the time the AC motor fails it's often time to consider replacing the entire system. One reason they last so long is they are designed and manufactured to withstand extreme heat up to 140℉.
What causes a condenser fan motor to overheat?
Not having the fan blades installed in a correct position can result in a lack of airflow and cause the motor to overheat. Lack of maintenance. If the motor has not been lubricated, or the unit kept clean, this can lead to overheating problems.
What happens if the condenser fan fails?
Another more serious symptom that the condenser fan has failed is the vehicle beginning to emit a burning odor. When the condenser overheats, all of the components of the AC system will begin to overheat until they eventually get hot enough to burn and emit an odor.
What is the purpose of a condenser fan motor?
For an air conditioner, the condenser fan motor is used to reject heat. For a heat pump, the condenser fan motor both rejects heat and pulls air into the condenser coil to absorb heat. Finally, there are times when the condenser fan motor will fail making a repair necessary.
Why does my fan stop running hot?
The most common problem associated with the condenser fan motor getting hot and then stopping is likely the fan capacitor. For a condenser the capacitor is typically a dual capacitor. The dual capacitor is a run capacitor that serves both the compressor and the condenser fan motor.
Do you need a drip plug on a fan motor?
That is called a drip plug, and you should also have one on the other end of the fan motor. The should be no plug on the downside of the motor. Furthermore, the plug on the top side of the motor should be clearly in place. Finally, this allows moisture that occurs as a result of condensation to drip out of the casing.
Is it normal for a heat pump to defrost?
The unit is in defrost, and it’s melting the ice and making little clouds of condensation when in defrost. This is normal for a heat pump to do this in the winter when in defrost mode, just like the fan motor not turning when in defrost mode.
What to do if condenser fan motor is not running?
If the condenser fan motor is receiving the correct voltage but the motor still won’t run, inspect the capacitor to ensure that it is not at fault. If the capacitor is not bulging or leaking, replace the condenser fan motor.
Why is my fan motor not running?
Common solutions for: Condenser fan motor does not run. If the capacitor is defective, the fan motor might be noisy, overheat, or not run at all. To determine if the capacitor has failed, inspect the capacitor. If the capacitor is bulging or leaking, replace it.